OHM-LABS, INC.
611 E. Carson St.
Pittsburgh, PA 15203

412-431-0640

866-431-0640

A2LA Accredited

CSW Working Standard Shunts
Lower Cost – High Accuracy

  • 100 mA to 300 A
  • Accuracy to 0.01 %
  • Accredited Cal Included

In response to customer demand for less than ‘state of the art’ measurement capability, Ohm-Labs has developed a new line of CSW Working Standard Shunts.

CSW shunts are rated to 100 % continuous current with no loss of accuracy. They are largely immune from connection errors common to many shunts. All CSW shunts include ISO17025 accredited calibration through full current range.

All Ohm-Labs shunts are warranted for two years.

 

Model Rated Amps Nominal
Resistance
Output at
Rated Current
Power Accuracy* Dimensions Weight
CSW-0.1 0.1 Amp 10 Ohm 1 Volt 1 Watt <0.01 %^ 10x15x5 cm

4x6x2 in

1 kg

2 lbs

CSW-1 1 1 1 1 <0.01
CSW-2 2 0.5 1 2 <0.02
CSW-5 5 0.2 1 5 <0.02
CSW-10 10 0.1 1 10 <0.025
CSW-20 20 0.02 0.4 8 <0.05
 

Replacements for Leeds & Northrup Shunts

CSW-15 15 0.1 1.5 22.5 <0.0125 20x30x10 cm

8x12x4 in

3 kg

5 lbs

CSW-100

CSW-100X

100 0.01 1 100 <0.03

<0.01

15x20x7.5 cm

6x8x3 in

3 kg

6 lbs

CSW-300 300 0.001 0.3 90 <0.05 30x15x7.5 cm

12x6x3 in

4 kg

8 lbs

Notes

  • Accuracy includes 0-100 % rated current, plus 18-30 °C operation, plus calibration uncertainty, plus predicted 12 month stability