OHM-LABS, INC.
611 E. Carson St.
Pittsburgh, PA 15203

412-431-0640

866-431-0640

A2LA Accredited

High Current Precision Shunts – to 3000 A

High Current Precision Shunts - to 3000 A

  • 500 to 3000 AMP MODELS
  • RATED FOR CONTINUOUS FULL CURRENT
  • GOOD LONG TERM STABILITY
  • ACCREDITED CALIBRATION INCLUDED

The CS-500 to CS-3000 Precision Current Shunts are designed for precise measurement of higher currents. A recent design upgrade has improved the accuracy of these shunts.

The CS-series shunts are rated for full continuous current with no loss of accuracy. Heat generated by the measurement current is adequately dissipated by the surface area of the exposed elements.

The CS-500 to CS-3000 are open, parallel blade construction. They have been found to agree well between DC and 50/60 cycles, but are not recommended for pulse or high frequency use.

All shunts INCLUDE ISO 17025 accredited calibration through full rated current.

For the highest precision applications, a temperature sensor can be bonded to the shunt element, and current / temperature characterization can be provided. Please see the Temperature Option for an example of this characterization. 100 ohm RTD, type T thermocouple and 10 K thermistor sensors are available.

Custom fitted transit cases are included with purchase.

Model Rated Current Nominal
Resistance Micro-Ohms
Millivolts at
Rated Current
Rated
Power
Accuracy Dimensions Weight
CS-500 500 200 100 50 W <0.02 % 60x10x13 cm 24x4x5 in 7 kg / 14 lbs
CS-1000 1000 100 100 100 W <0.025 % 70x13x13 cm 28x5x5 in 17 kg / 36 lbs
CS-1500 1500 40 60 90 W <0.04 % 48x13x13 cm 19x5x5 in 15 kg / 32 lbs
CS-2000 2000 20 40 80 W <0.04 % 48x18x13 cm 19x7x5 in 22 kg / 48 lbs
CS-3000 3000 10 30 90 W <0.04 % 38x18x13 cm 15x7x5 in 20 kg / 45 lbs
Special Values available on request – use the following format (accuracy may be derated)
Specify
CS-X-Y
X = Rated Amps Y = Rated
Millivolts
CS-500-100 = 500 A, 100 mV, 0.000 2 ohm
CS-250-100 = 250 A, 100 mV, 0.000 4 ohm

Notes

  • Stated accuracy at time of manufacture.
  • Accuracy is through full range of applied current, at 18-30 °C
  • All Ohm-Labs’ shunts carry a two year warrantee.